Dongli Fuhua House
Specification and model Optional items Product Video
Structural drawing of drying room
Function introduction
This drying room is a large drying room with an effective volume of about 87m3 and a maximum drying temperature of 150 ℃,
Three sets of hot air circulation system, with strong wind and reasonable air distribution. Centralized control, SCR+PID control is adopted for each set of heating, with high precision, large drying amount and good effect.
Operation sequence (startup)
Turn on the power switch, turn on the air supply button, turn on the heating button
Operation sequence (shutdown)
Turn off the heating button Turn off the air blower Turn off the power
Working principle:
The drying room is composed of insulation room, air blower, heat exchange room, air duct pipeline and control system,
The air is heated in the heat exchange room and sent to the drying room through the hot air blower to mix with the air in the drying room and participate in the heat exchange. The mixed air enters the heat exchange room again for heating, and then is sent to the drying room for heat exchange (convection) after heating, so as to achieve the purpose of heating repeatedly in turn.
characteristic:
1. The fan has large air volume, large penetration, small static pressure and stable operation.
2. Large internal space and large amount of drying at one time;
3. The air flow in the drying room is reasonable and the temperature is uniform;

Product introduction
Maintenance
1. Regularly check the heating tube and replace it if it is damaged
2. Regularly check the fan and maintain the motor
Troubleshooting:
fault reason Corrective methods
Inactive
1) Power failure
2) The power switch is not connected
3) Power switch fuse is blown
1) Wait for the power supply to return
2) Close the switch
3) Replace the fuse
Insufficient air volume
1) Fan reversal
2) Air leakage occurs
1) Reconnect the power cord in reverse
2) Sealing
Uneven air volume
1) One group of fans may stop running
2) Unstable voltage affects the fan operation, resulting in air volume fluctuation
1) Overhaul
2) Check the power consumption and solve it again
After sales service
When using the equipment produced by our company, if there is any abnormal phenomenon in the process, please call at any time, and our company will assign technicians to repair and deal with it in a timely manner. Maintenance hotline: 0512 - 66300668 - 816,
Service hotline: 138625766668 Mr. Wei